交流電流 |
Range |
0-999.9A |
Accuracy |
2% ±
5counts (50/60 Hz)
6% ±
5counts (100-400Hz) |
Crest Factor |
3
@ 500A,
2.5 @ 600A
1.42 @ 1000A
add 2% for C.F. >2
|
AC Response |
True-rms |
In-rush
量測 |
100 mS
|
直流電流 |
|
Range |
0-999.9A
|
Accuracy |
2% ±
3counts
|
交流電壓 |
Range |
0-600.0V
|
Accuracy |
1% ±
5counts (50/60 Hz)
6% ±
5counts (100-400Hz)
|
AC Response |
True-rms |
直流電壓 |
Range |
0-600.0V
|
Accuracy |
1% ±
5counts
|
電阻 |
Range |
0-600.0 Ω,
600-6000Ω
|
Accuracy |
1.5% ±
5counts
|
通斷測試 |
Range |
≦ 30Ω
|
|
頻率
(AC only) |
Range |
5-400 Hz
|
Accuracy |
0.5% ±
5counts
|
Trigger Level |
10-100Hz ≧ 5A
5-10Hz
& 100-400Hz ≧ 10A
|
最大/最小值 |
YES |
背光 |
YES
|
體積 (inch) |
9.375 * 3.125* 1.625 (H.W.D)
|
重量 |
11 oz.
|
其他規格 |
電池壽命 |
鹼性電池約
150
小時,具有低電量指示。 |
操作溫度 |
-10 to +50℃, -14 to 122 ℉
|
安全規格 |
IEC 1010-2-301A, 600V CAT-III |
標準配件 |
-
Soft Carrying Case
-
TL75 Test Leads
-
(2)AA Alkaline Batteries
-
Coated Instruction Card
-
Safety Information Sheet
|
選購配件 |
|
|